Updated Th11 24, 2026· 16 min read

Key takeaways

  • Five smart thermostats with real auxiliary heat controls for heat pumps, comparing outdoor lockout settings, balance points, staging, and dual fuel handling.

As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.

Every heat pump owner knows the sound of an expensive morning: the outdoor unit straining in cold air while the auxiliary heat strips, which are really just large electric resistance heaters, run alongside it and spin the meter. Auxiliary heat has a proper job, covering defrost cycles and the coldest hours when the compressor alone cannot keep up, but left unmanaged it joins in far too early and far too often, and a heat pump that leans on its strips loses the efficiency that justified buying it. The thermostat is the manager. That is why the best smart thermostats with heat pump auxiliary heat controls are judged less on their touchscreens than on their installer settings: the lockout temperatures, balance points, and staging rules that decide when auxiliary heat may run, when it must wait, and when the compressor should be left to work alone.

The five thermostats below all control heat pumps with auxiliary heat, and all expose genuine auxiliary controls rather than a single hidden default. They approach the job from different directions: outdoor-temperature lockouts that forbid auxiliary heat above a set temperature, balance point logic that weighs the compressor's falling capacity against the house's rising heat loss, and dual fuel handling for homes where the backup is a furnace instead of strips. Each section sticks to the controls the maker actually documents, because in this category the difference between a thermostat that manages auxiliary heat and one that merely switches it is measured in winter bills.

Quick verdict

The Honeywell Home T10 Pro leads for auxiliary control depth in a professionally finished package, with three heat and two cool stages on heat pump systems, installer-set compressor lockout, a dedicated emergency heat mode, and terminals for auxiliary and emergency heat as separate circuits. The Honeywell Home T6 Pro Smart is the straightforward lockout pick: its maker's submittal sheet states auxiliary heat lockout using an outdoor sensor or internet weather in plain language. The ecobee Smart Thermostat Essential brings ecobee's threshold-based approach, including a maximum outdoor temperature for auxiliary heat, at the line's entry tier. The Google Nest Thermostat covers the basics honestly, with auxiliary and compressor lockouts and Heat Pump Balance in Google's own comparison chart. The Sensi Touch 2 is the settings specialist, with documented balance point and auxiliary lockout set points and automatic dual fuel control that needs no outdoor sensor.

Model Heat pump staging Auxiliary control style Outdoor reference Dual fuel Sensor options
Honeywell Home T10 Pro 3H/2C heat pump Installer lockouts, compressor lockout, emergency heat mode Wired outdoor sensor input Yes, with backup heat configuration Up to 20 wireless RedLINK sensors
Honeywell Home T6 Pro Smart 2H/1C heat pump Auxiliary heat lockout per maker submittal Outdoor sensor or internet weather On the 3H/2C sibling model Optional wired sensors
ecobee Smart Thermostat Essential 2H/1C heat pump Outdoor-temperature thresholds for auxiliary heat Internet weather Limited SmartSensor sold separately
Google Nest Thermostat 1H/1C heat pump Auxiliary lockout plus Heat Pump Balance Internet weather Hybrid heat listed No remote sensor support
Sensi Touch 2 4H/2C heat pump Balance point and auxiliary lockout set points No outdoor sensor required for dual fuel logic Yes, automatic Sensi Room Sensors sold separately

How we chose

The first gate was documented auxiliary control. Each thermostat had to offer more than an auxiliary terminal: the maker's own manual, submittal sheet, specification sheet, or comparison chart had to name a lockout, a balance point, or a threshold setting that governs when auxiliary heat runs. Thermostats whose auxiliary behavior is a fixed factory default with no user or installer adjustment were excluded, however good their other features.

The second gate was heat pump staging breadth. Auxiliary control means little on a thermostat that cannot stage the equipment in the first place, so published stage counts for heat pump systems were compared, from single-stage compressor systems with one auxiliary stage up to multi-stage arrangements with separate emergency heat. Dual fuel support was recorded separately, because a home backing its heat pump with a gas furnace needs changeover logic, not strip management.

The third gate was the outdoor reference. A lockout is only as good as the temperature it reads, so each pick was checked for how it learns the outdoor temperature: a wired sensor, internet weather, or an internal method that needs neither. Finally, everyday qualities still counted: a thermostat whose settings are buried beyond reach will be left at defaults, so the clarity of each maker's documentation and setup flow carried weight. Every claim below comes from a document published by the maker, and prices are omitted because they change too often to print.

Honeywell Home T10 Pro

  • Staging: Up to 3 heat and 2 cool stages on heat pump systems
  • Terminals: Aux for backup heat and E for emergency heat as separate circuits
  • Controls: Installer setup includes compressor lockout and stage activation settings
  • Modes: Dedicated Em Heat mode locks out the heat pump and runs backup heat
  • Sensors: Up to 20 wireless RedLINK indoor sensors, 200-foot range, sensor included with THX321WFS2001
  • Power: 24 VAC C wire required
  • Recovery: Adaptive Intelligent Recovery learns system response
  • Size: 4.9 x 3.7 x 0.93 inches

The T10 Pro is the installer's thermostat in this group, and its auxiliary story is one of structure. Auxiliary and emergency heat land on separate terminals, so the strips that supplement the compressor and the backup that replaces it in an emergency are wired and controlled as the different things they are. Setup walks the installer through compressor lockout and stage activation, and the thermostat's installer settings carry the auxiliary lockout temperatures that decide how cold it must be before backup heat may join. The Em Heat mode is the manual override done properly: one selection locks the heat pump out and runs the backup, for the night the outdoor unit ices over or fails outright. Add support for up to 20 wireless room sensors and Adaptive Intelligent Recovery, which learns how the house responds so recovery from a setback does not panic the system into auxiliary heat, and the package is complete.

The costs are the professional framing. The T10 Pro is sold through pro channels, needs a C wire without exception, and its deepest settings live in installer menus that many owners will never open, so the quality of the installation matters as much as the thermostat. Owners who want to tune thresholds from an app on the sofa may find the ecobee approach friendlier. It also does not work with line-voltage baseboard or millivolt systems.

Pros:

  • Separate auxiliary and emergency heat circuits, properly distinguished
  • Installer lockouts for compressor and auxiliary behavior
  • Dedicated emergency heat mode for equipment failures
  • Room for up to 20 wireless sensors at 200-foot range

Cons:

  • Pro-channel product whose deep settings sit in installer menus
  • C wire required, no battery fallback
  • Not for line-voltage or millivolt systems

Honeywell Home T6 Pro Smart

  • Staging: Up to 2H/1C on heat pump systems, 2H/2C conventional (TH6220WF2006)
  • Auxiliary control: Auxiliary heat lockout with outdoor sensor or internet weather, per the maker's submittal sheet
  • Sibling model: TH6320WF2003 offers 3H/2C heat pump with dual fuel and auxiliary heat lockout
  • Scheduling: 7-day, 5-2, 5-1-1, 1-week, or geofencing through the Resideo app
  • Connectivity: 2.4 GHz WiFi, Apple HomeKit and Alexa
  • Power: 24 VAC to Rc and C required, no batteries
  • Certification: ENERGY STAR certified
  • Size: 4-1/16 H x 4-1/16 W x 1-5/32 D inches

The T6 Pro Smart earns its place on one sentence of its maker's submittal sheet: auxiliary heat lockout with outdoor sensor or internet weather. That is the single most valuable auxiliary control for a typical heat pump home, stated plainly, with two ways to feed it the outdoor temperature. Wire the maker's outdoor sensor and the lockout reads the air at your own house; skip the sensor and the thermostat pulls weather from the internet instead, which keeps the feature available on a simple two-wire swap where running a sensor cable is impractical. The rest of the thermostat is Honeywell's dependable midrange: flexible scheduling or geofencing, HomeKit and Alexa support, and a square touchscreen that disappears into most walls.

The boundaries are the staging and the radio. The TH6220WF2006 covered here stages a heat pump at 2H/1C, so a two-stage compressor with two auxiliary stages belongs on the TH6320WF2003 sibling, which also adds dual fuel handling and ventilation control; confirm which model is in the box before an installer visit. WiFi is 2.4 GHz only, and power requires Rc and C with no battery option, so a missing common wire means the maker's adapter or another pick.

Pros:

  • Auxiliary heat lockout stated plainly in the maker's own submittal
  • Lockout can read a wired outdoor sensor or internet weather
  • Geofencing and flexible scheduling in the Resideo app
  • ENERGY STAR certified, HomeKit support

Cons:

  • This model stages heat pumps at 2H/1C; deeper staging needs the sibling model
  • 2.4 GHz WiFi only
  • C wire required with no battery fallback

ecobee Smart Thermostat Essential

  • Staging: Heat pump 2H/1C per maker specifications
  • Auxiliary control: ecobee threshold settings, including a maximum outdoor temperature for auxiliary heat and a minimum outdoor temperature for the compressor
  • Sensors: Works with ecobee SmartSensor, sold separately, for occupancy-aware comfort
  • Display: Full-color touchscreen
  • Power: Power Extender Kit sold separately for homes without a C wire
  • Savings: eco+ energy features, ENERGY STAR certified
  • Platforms: Apple Home, Alexa, Google Assistant
  • Warranty: 3-year limited

The Essential carries ecobee's threshold philosophy at the line's entry tier. Instead of a single lockout, ecobee exposes the relationship as settings: an outdoor temperature above which auxiliary heat may not run at all, and a lower threshold where the compressor itself is rested and the backup takes over. Set those two numbers with your climate and your equipment's real capacity in mind, and the thermostat manages the shoulder-season mornings, when auxiliary heat most often sneaks in unneeded, without further attention. The Essential also joins the SmartSensor system, gaining occupancy-aware eco+ behavior with a paired sensor, and it keeps the platform's clear app and energy reports.

The compromises are the tier's edges. Staging is 2H/1C on heat pumps, so multi-stage auxiliary arrangements are beyond it. The Power Extender Kit, included with ecobee's higher models, is a separate purchase here if your home lacks a C wire, and the first-generation ecobee Room Sensor is not compatible, only the current SmartSensor. Owners of larger heat pumps with two compressor stages should look at the ecobee Enhanced or Premium, or at the Sensi Touch 2.

Pros:

  • Threshold-based auxiliary and compressor control, adjustable from the app side
  • SmartSensor support brings occupancy-aware savings
  • ENERGY STAR certified with a 3-year warranty
  • Entry tier of a mature, well-documented platform

Cons:

  • Heat pump staging limited to 2H/1C
  • Power Extender Kit sold separately
  • Not compatible with the first-generation ecobee Room Sensor

Google Nest Thermostat

  • Staging: Up to 1H/1C heat pump or hybrid heat per Google's comparison chart
  • Auxiliary control: Auxiliary heat lockout and compressor lockout listed in Google's chart
  • Heat pump feature: Heat Pump Balance
  • Occupancy: Home and Away Routines using phone location and device sensing
  • Display: Mirrored display
  • Fan: Single-speed fan control
  • Sensors: Not compatible with Nest Temperature Sensors
  • Power: Works without a C wire in many homes, per Google

Google's entry-level thermostat is the minimalist in this group, and its auxiliary controls are correspondingly plain but real. Google's own comparison chart lists both an auxiliary heat lockout and a compressor lockout for this model, alongside Heat Pump Balance, the feature that lets the thermostat trade recovery speed against auxiliary use rather than slamming the strips on whenever the house is a few degrees behind. Home and Away Routines trim the baseline problem, since a house held at an eco temperature while empty needs less recovery, and therefore less auxiliary help, when the family returns. The mirrored display and simple interface suit owners who want the equipment managed without a settings hobby.

The limits are firm. One heat and one cool stage on heat pump systems is the ceiling, so two-stage compressors and staged auxiliary banks are out. There is no remote sensor support at all on this model, which rules it out for room-balancing projects. Fan control is single-speed. This is the right thermostat for a simple single-stage heat pump in a small home, and the wrong one for almost any larger installation.

Pros:

  • Auxiliary and compressor lockouts documented in Google's own chart
  • Heat Pump Balance tempers auxiliary use during recovery
  • Simple interface and Home and Away Routines
  • Flexible power, works in many homes without a C wire

Cons:

  • Single-stage heat pump support only, 1H/1C
  • No remote room sensor compatibility
  • Single-speed fan control

Sensi Touch 2

  • Staging: Heat pump 4H/2C per the maker's specification sheet
  • Auxiliary control: Set points for balance point and auxiliary lockout in heat pump settings
  • Dual fuel: Automatic dual fuel control without an outdoor sensor
  • Sensors: Sensi Room Sensors sold separately, about 100 feet of range
  • Display: Glass color touchscreen, 5.6 W x 3.25 H x 0.77 D inches
  • Connectivity: Dual-band 2.4 and 5 GHz WiFi plus Bluetooth LE
  • Power: C wire required for all systems, common wire kit available
  • Certification: ENERGY STAR certified, Title 24 compliant
  • Warranty: 3-year limited

The Sensi Touch 2 is the control-room pick. Copeland's specification sheet describes its heat pump settings in the vocabulary installers actually use: a balance point, the outdoor temperature where the house's heat loss overtakes the compressor's capacity, and an auxiliary lockout, the temperature above which the strips stay off regardless. Giving the owner both set points, rather than one blended behavior, is what separates management from switching. The automatic dual fuel control deserves its sentence too: the thermostat handles a heat pump backed by a fossil fuel furnace without needing an outdoor sensor, deciding changeover from its own logic. Four heat stages on heat pump systems give those settings equipment to work with, and the glass touchscreen presents it all clearly.

The trade-offs are the usual Sensi ones. A C wire is required for every system, with a kit as the workaround. The room sensors that would let it balance rooms as well as stages are a separate purchase. And while the settings are admirably explicit, they reward an owner willing to learn what a balance point is; set carelessly, a low lockout can leave a house cold on the one night the compressor truly cannot cope, so the maker's defaults deserve respect until the system's behavior is understood.

Pros:

  • Balance point and auxiliary lockout as separate, documented set points
  • Automatic dual fuel control with no outdoor sensor to wire
  • Deepest heat pump staging here at 4H/2C
  • Dual-band WiFi, ENERGY STAR certified, 3-year warranty

Cons:

  • C wire required for all systems
  • Room sensors sold separately
  • Explicit settings reward an informed owner and installer

Buying guide

Learn your own system before choosing. Count the stages from the equipment nameplates or the existing thermostat's wiring: a single-stage compressor with one bank of strips is a 2H/1C world where the T6 Pro Smart, the ecobee Essential, or even the Nest Thermostat can manage well, while a two-stage compressor or split auxiliary banks need the staging depth of the T10 Pro or the Sensi Touch 2. Note whether your backup is electric strips or a furnace, because dual fuel homes are choosing changeover logic, and the Sensi Touch 2's sensor-free dual fuel control and the T10 Pro's structured setup are the relevant features there.

Understand the two numbers that run the show. The auxiliary lockout is a ceiling: above that outdoor temperature, auxiliary heat may not run, full stop, and setting it well is the single biggest saver for most homes, because shoulder-season mornings are where strips waste the most hours. The balance point is an estimate of where your compressor stops keeping up, and it depends on your house's insulation and your unit's capacity, not on a national chart. A thermostat that exposes both, like the Sensi Touch 2, or ecobee's paired thresholds, lets an installer tune the system to the house; a single lockout, like the T6 Pro Smart's, is simpler and still captures most of the savings.

Decide how the thermostat will know the outdoor temperature. A wired sensor at your own house, as the T10 Pro and T6 Pro Smart accept, reads the microclimate that actually matters, including the cold hollow behind the building. Internet weather, which the T6 and the ecobee and Nest models can use, costs nothing to install and is usually close, but it can lag a fast cold front by enough to matter on the margin. The Sensi Touch 2 sidesteps the question for dual fuel control entirely.

Finally, keep an emergency path. However good the lockouts are, there will be a night when the compressor fails or ices and the backup becomes the heating system. A dedicated emergency heat mode, like the T10 Pro's Em Heat, or a thermostat whose settings you understand well enough to force auxiliary heat manually, is part of auxiliary control too. Set the lockouts firmly, but know how to lift them before the coldest week of the year, not during it.

FAQ

What is an auxiliary heat lockout, in plain terms?

It is a temperature rule: when the outdoor air is warmer than the lockout setting, the thermostat refuses to run auxiliary heat and lets the compressor do the whole job, even if recovery takes longer. Because auxiliary strips cost far more per unit of heat than the heat pump itself, a well-set lockout is usually the largest single saving available to a heat pump owner.

What is a balance point, and how is it different from a lockout?

The balance point is the outdoor temperature where your heat pump's output exactly matches your home's heat loss. Below it, the compressor alone cannot hold the setting and auxiliary help is legitimate. A lockout is a policy limit you choose; a balance point is a physical property of your house and equipment that a good thermostat, like the Sensi Touch 2, lets you enter so its staging decisions follow the physics.

Why does auxiliary heat run during defrost, and should I stop it?

During a defrost cycle the heat pump briefly reverses to melt frost from the outdoor coil, which would blow cool air indoors, so the system runs the strips for a few minutes to temper the air. That is auxiliary heat doing its proper job, and no lockout should be set in a way that fights it. The waste worth attacking is auxiliary heat joining during ordinary recovery on mild days, which is what lockouts and Heat Pump Balance address.

My backup is a gas furnace, not strips. Which controls matter then?

You need dual fuel or hybrid heat control: logic that runs the heat pump in mild weather, switches to the furnace below a changeover temperature, and never runs both in a way the equipment forbids. The Sensi Touch 2 offers automatic dual fuel control without an outdoor sensor, the T10 Pro supports backup heat configurations in its installer setup, and Google's chart lists hybrid heat for its models. Confirm your exact equipment pairing against the maker's compatibility tool.

Can internet weather replace a wired outdoor sensor?

For lockout purposes, usually yes, and the T6 Pro Smart explicitly offers either source. Internet weather is free and effortless, but it reports a nearby station rather than your yard, and it can trail a fast-moving cold front. A wired sensor reads your own microclimate and keeps working if the internet drops. Homes chasing the last few percent of auxiliary savings, or sitting in a frost hollow, benefit from the wired sensor.

Will tighter auxiliary settings leave my house cold?

They can if they are set below the system's real balance point, which is why settings should start from the maker's defaults and move in small steps while you watch a few cold mornings. The goal is not to ban auxiliary heat; it is to stop it running when the compressor could have done the job alone. Every thermostat here keeps an emergency heat path for the nights the backup truly is the heating system.

Conclusion

Auxiliary heat is not the enemy; unmanaged auxiliary heat is. The thermostat that saves a heat pump owner real money is the one whose lockouts, balance points, and staging rules match the equipment in the yard and the house around it. The Honeywell Home T10 Pro offers the most structured professional control, the T6 Pro Smart the clearest single lockout, the ecobee Essential threshold control at an entry tier, the Nest Thermostat honest basics for simple systems, and the Sensi Touch 2 the most explicit settings of all. Read your nameplates, learn your balance point, and set the lockout with intent, and the strips go back to their proper job: rare, brief, and genuinely needed.

A
admin88
We compare specs, warranty terms, long-term owner feedback and street pricing before anything earns a spot. Rankings are never paid.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases at no extra cost to you. Prices accurate as of the date shown.

Related guides